Enter your keyword

2-s2.0-85086798246

[vc_empty_space][vc_empty_space]

Calculation of Size-Specific Dose Estimation (SSDE) of the Pediatric’s Head for Tube Current Modulation (TCM) CT Examinations

Syaja’Ah K.N.a, Anam C.b, Lestari F.P.a, Haekal M.a, Haryanto F.a

a Department of Physics, Faculty of Mathematic and Natural Science, Institut Teknologi Bandung, Indonesia
b Department of Physics, Faculty of Mathematics and Natural Sciences, Diponegoro University, Semarang, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© Published under licence by IOP Publishing Ltd.Computed Tomography (CT) examinations in the pediatric patient are sensitive to the impact of ionizing radiation, which gives long-term risk. In addition, the actual radiation dose delivered during CT examinations has not been well-described mainly when using tube current modulation (TCM) technique. To quantified this effect, an algorithm for calculating radiation dose is needed. Therefore, this study aims to calculate and analyze the estimated effective dose of head examinations from 3D CT images, based on the equivalent water diameter (Dw)For the TCM technique. Four pediatric patients in the 0-6-year-old age groups were examinations using Somatom Definition Flash with variation in the number of slices. CTDIvol and Tube current values were obtained from the DICOM header. There are two main parts algorithm for Dw calculation. First, images of CT data were converted to Hounsfield units (HU). Then, Dw values based on the patients contour using the K-mean cluster and morphological gradient algorithm were calculated for every slice. The coefficient factor is obtained by American Association of Physicists in Medicine (AAPM) report 220. The values then multiplied by CTDIvolto acquire values of SSDE. The results showed that the relation between SSDE and tube current was strongly correlated with R2 values of 0.982.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Dose estimations,Effective dose,Hounsfield units,Long-term risks,Morphological gradient,Pediatric patients,Tube current modulations,Tube currents[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1088/1742-6596/1505/1/012036[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]