Enter your keyword

2-s2.0-85088925856

[vc_empty_space][vc_empty_space]

Challenges and opportunities for septage management in the urban areas of Indonesia – Case study in Bandung City

Bao P.N.a, Abfertiawan M.S.b,c, Kumar P.a, Hakim M.F.c

a Institute for Global Environmental Strategies, Hayama, 2108-11, Japan
b Water & Wastewater Engineering Research Group, Faculty of Civil and Environmental Engineering, Institut Teknologi Bandung, Bandung, 40132, Indonesia
c Ganeca Environmental Services, Bandung, 40287, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2020 Published by ITB Institute for Research and Community Services.Because of the burgeoning urban population, there is huge pressure on both natural resources and basic urban infrastructure, especially sewerage systems, with Indonesia as no exception. It is estimated that about 95% of human waste in Indonesia ends up untreated or partially treated in septic tanks before being discharged in the natural environment, contaminating the living environment as well as adversely affecting human health and economic development. This study conducted a comprehensive investigation on septage management in Bandung City, Indonesia, to gain a better understanding of the challenges and opportunities for improved performance of on-site sanitation systems as well as septage management across its sanitation service chain. The results showed that the following issues are the main reasons behind poor sanitation in Bandung city: a) poor design and construction of septic tanks with no or only partial lining, resulting in leaking (>90% of septic tanks are malfunctioning); b) irregular desludging, i.e. about 2/3 of population desludge their septic tanks only once in more than 5 years; c) lack of proper guidelines and awareness about the benefits of regular monitoring and operation of septic tanks; d) lack of good sanitation service providers; and e) lack of funds for building sufficient capacity of septage treatment plants.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Design and construction,Living environment,Natural environments,On-site sanitation systems,Sanitation services,Septage management,Septage treatment,Urban infrastructure[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text]The authors would like to express their gratitude to the Ministry of the Environment of Japan for providing financial support through the project Integrated Approach for Dissemination of Decentralized Domestic Wastewater Treatment System in Southeast Asia (1-1603).[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.5614/j.eng.technol.sci.2020.52.4.3[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]