[vc_empty_space][vc_empty_space]
Applied current injection and magnetic field induction simultaneously on electrical impedance tomography
Darmawan D.a,b, Kurniadi D.a, Suyatmana, Janivitaa
a Instrumentation and Control Research Group, Institut Teknologi Bandung, Bandung, Indonesia
b Non Destructive Testing Research Group, Telkom University, Bandung, Indonesia
[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2016 by CESER PUBLICATIONS.Ill-posed problem is an important issue arises in electrical impedance tomography. The nonlinearity of the system, lack of sensitivity, and lack of data reconstruction are the causes of ill-posed. Merging of multiple modalities adds data reconstruction, but it increasesa nonlinearities of the system. The uses of only two modalities, namely current injection system and induced magnetic field system, but with a combination of a data collection system configuration is sufficient to increase the amount of information. On the other hand, the complexity of the system and the degree of nonlinearity are not too high. Some simultaneous combination of two modalities was conducted to the rectangular object. The work was focused to identify anomalies position far away from the boundary. The results show that a decrease in errors of reconstruction in line with the addition of the number of retrieved data.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Amount of data,Current injection,Ill-posed problem,Magnetic field induction,Rectangular object,Two modalities[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]