Enter your keyword

2-s2.0-85085866236

[vc_empty_space][vc_empty_space]

Lightning Protection System on Substation Extra High Voltage 500 kV Sumatera, Indonesia

Irsal A.a, Denov B.a, Zoro R.a

a School of Electrical Engineering and Informatics, Bandung Institute of Technology, Bandung, West Java Province, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2019 IEEE.The National Electricity Company in Indonesia is planning to build a 500 kV power transmission system in Sumatera, Indonesia. Sumatra Island is an island that has a high intensity of lightning strikes every year. This is because the island of Sumatra is in the tropics and is in the Monsoon wind line. The conditions for the occurrence of Cumulonimbus Clouds are easily met, namely up-draft, aerosol, and humid air. Lightning disturbances at the substation are divided into two, traveling wave from the transmission and the direct lightning strokes at the substation. Traveling waves from the transmission can cause flashover in equipment. While direct lightning strokes at the substation can cause backflashover in the insulator of rod structure and flashover in the equipment. Therefore, a lightning protection system is needed in the substation. The solution for traveling waves from transmission is insulation coordination. The solution for direct lightning strokes on substations is rod structure that protects substation equipment and installation of arresters.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Direct lightning stroke,Electricity companies,Extra high voltage,Lightning disturbances,Lightning protection systems,Lightning strikes,Power transmission systems,Substation equipment[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]500 kV,Lightning,Protection,Substation,Sumatera[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text]I would like to thank PLN (Perusahaan Listrik Negara), Indonesia Electric Power Company for all data that has been given.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/ICEEI47359.2019.8988784[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]