Enter your keyword

2-s2.0-85082017981

[vc_empty_space][vc_empty_space]

Lightning Protection System for High Voltage Transmission Line in Indonesia

Zoro R.a, Atmajaya G.K.M.a, Denov B.a

a School of Electrical Engineering and Informatics, Bandung Institute of Technology, Bandung, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2019 IEEE.Based on the outage data released by Indonesia Electricity Company (PLN), the line-outages occurred at trnasmission line in Indonesia is very high, 49% occured at 150 kV line and almost 69% in 70 kV lines all over Indonesia. This reserch was carried out at 70kV transmission line in Malang, an area located at south part of east Java, Indonesia which is mostly suffered due to lightning strikes. Transmission towers in this arew were being the easy target of lightning strikes due to their height of more than 30 meter, have only one erth wire and most of them are located on the open area. Lightning strikes to towers produced back flashover on the insulator and lead to the blackouts on the system. This research analyzes the performance of the 70kV high voltage transmission line against lightning strikes based on installed lightning protection devices. A protedction system is introduced to improve the performance of the transmission line against lightning strikes by installing Extended Mast Terminal (EMT) on the transmission tower. EMT is a lightning protection system equipped with Early Streamer Emission (ESE) as an Air Terminal to attract the lightning strikes, low inductance lightning down conductors, integrated grounding system and a panel at the bottom of the cable to record the number of lightning strikes and the peak current of lightnuing detector.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Down-conductors,Electricity companies,Grounding systems,High voltage transmission lines,Lightning protection devices,Lightning protection systems,Lightning strikes,Transmission tower[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]70 kV overhead lines,EMT,Lightning Protection System[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/ICHVEPS47643.2019.9011069[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]