Enter your keyword

2-s2.0-85054618121

[vc_empty_space][vc_empty_space]

Analysis of explosion risk factor potential on coal reclaim tunnel facilities by modified analytical hierarchy process

Widodo N.P.a, Sulistianto B.a, Ihsan A.a

a Mining Engineering Group, Faculty of Mining and Petroleum Engineering, Institut Teknologi Bandung, Bandung, 40132, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2018, The Author(s).This study focused on developing a risk assessment method for explosion at a coal reclaim tunnel (CRT) facility. The method was developed based on an analytical hierarchy process (AHP), which is an expert system that quantifies the factors of explosion incidents, based on events and hierarchies. In this paper, the proposed model was modification from original AHP model, specifically modifying the structure from “alternative’s results” to “total risk-rating’s results”. The total risk-rating is obtained by summing up risk-rating of each factor, where the risk-rating is a multiplication product of the risk value by the AHP weighted value. To support decision-making using the expert system, data on the real conditions of the CRT were collected and analyzed. A physical modeling of the CRT with laboratory-scale experiments was carried out to show the impact of a ventilation system in CRT on diluting the methane gas and coal dust, in order to support the quantification of AHP risk value. The criteria to evaluate the risk of explosion was constructed from six components that are: fuel, oxygen, ignition, confinement, dispersion, and monitoring system. Those components had fifty-two factors that serve as sub-components (root causes). The main causes of explosion in CRT were found to be: mechanical ventilation failure and abnormal ventilation, breakdown of monitoring system, and coal spontaneous-combustion. Assessments of two CRT facilities at Mine A and Mine B were carried out as a case study in order to check the reliability of the developed AHP method. The results showed that the risk rating of Mine A was classified as high and Mine B was classified as medium, which is in a good agreement with the site conditions.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Analytical Hierarchy Process,Coal spontaneous combustion,Explosion incidents,Mechanical ventilation,Monitoring system,Risk assessment methods,Risk of explosions,Ventilation systems[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Analytical hierarchy process,Coal reclaim tunnels,Explosion,Risk[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1007/s40789-018-0219-0[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]