Enter your keyword

2-s2.0-85085565862

[vc_empty_space][vc_empty_space]

Actinide Minor Addition on Uranium Plutonium Nitride Fuel for Modular Gas Cooled Fast Reactor

Syarifah R.D.a, Su’ud Z.b, Basar K.b, Irwanto D.b

a Physics Department, Faculty of Mathematics and Natural Science, Jember University, East Java, Indonesia
b Nuclear Physics and Biophysics Research Division, Physics Department, Faculty of Mathematics and Natural Science, Bandung Institute of Technology Indonesia, Bandung, 40132, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2020 Published under licence by IOP Publishing Ltd.This study has made a calculation of Actinide Minor Addition on Uranium Plutonium Nitride Fuel for Modular Gas Cooled Fast Reactor. The purpose of this study was to determine the characteristics of minor actinides when incorporated into plutonium nitride uranium fuel. Neutronics calculation was design by using SRAC Code version 2006 (Standard Reactor Analysis Code) with the data nuclides from JENDL-4.0 under the Linux Operating System with nuclear data library JENDL4.0. Neutronic calculations were done through some steps of parameter survey to obtain the ultimate optimization results. The initial calculation was calculation of fuel cell (PIJ calculation) by using hexagonal cell and then followed by calculation of core reactor (CITATION calculation) by using program code SRAC2006. The addition of minor actinide has been calculated in this research. The minor actinides which were added were americium (Am-241 and Am-243) and neptunium 237. They were put into the uranium plutonium nitride material to decrease the k-eff value. The addition of minor actinide into the reactor aimed to reduce the number of minor actinides in the world. Minor actinide is a nuclear waste fuel or often called spent nuclear fuel (SNF) which has high toxicity. Neptunium 237 is a minor actinide with the highest percentage of SNF.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Gas cooled fast reactors,Hexagonal cells,LINUX- operating system,Neutronic calculations,Nitride materials,Nuclear data library,Reactor analysis,Spent nuclear fuels[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1088/1742-6596/1493/1/012020[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]