Enter your keyword

2-s2.0-84872923202

[vc_empty_space][vc_empty_space]

Phase unwrapping using energy minimization methods for MRI phase image

Adi K.b, Mengko T.L.R.b, Suksmono A.B.b, Gunawan H.b

a Institut Teknologi Bandung, Indonesia and Universitas Diponegoro, Indonesia
b Institut Teknologi Bandung, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]Phase Unwrapping (PU) is reconstruction of absolute phase data from its wrapped phase. The absolute phase cannot be extracted from the wrapped phase data directly. Without phase noise, singularity, and aliasing problems, the phase information can be unwrapped easily. However, the phase data are always contaminated by noise and discontinuities, making the PU process more complicated. Therefore, a suitable PU algorithm is required to address the problems properly. In this method, the energy difference between neighborhood pixels in level 3 is counted, followed by getting the probability value to obtain its total fringes. The capability of the proposed method to unwrap simulated and actual MRI phase images is also demonstrated. In actual MRI phase image, PU can be implemented for water and fat separation. Copyright © 2010, IGI Global.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Algorithm,Energy Minimization,MRI Phase Images,Phase Data,Phase Unwrapping[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text]This research is partly supported by Directorate General Higher Education (DIKTI) – Ministry of National Education Indonesia.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.4018/jehmc.2010070105[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]