Enter your keyword

2-s2.0-85100209188

[vc_empty_space][vc_empty_space]

APLICATION of BUTTERWORTH HIGH PASS FILTER AS AN APPROXIMATION of WOOD ANDERSON SEISMOMETER FREQUENCY RESPONSE to EARTHQUAKE SIGNAL RECORDING

Matondang H.H.a, Joelianto E.b, Widiyantoro S.b

a BMKG, Jakarta, Indonesia
b ITB, Bandung, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2020 International Measurement Confederation (IMEKO). All rights reserved.The method for generating maximum amplitude and signal to noise ratio values by using second order high pass Butterworth filter on local seismic magnitude scale calculations is proposed. The test data are signals from local earthquake that have been occurred in Sunda Strait on April 8th 2012. Based on the experimental results, a 8 Hz cutoff frequency and a gain of 2200 of second order Butterworth high pass filter as an approach to simulating the frequency response of Wood Anderson seismometer can provide maximum amplitude value, SNR, and the magnitude better than simulated Wood Anderson frequency response.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Frequency Response Simulation,High Pass Butterworth Filter,Instrument Correction,Wood Anderson Seismometer[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.21014/ACTA_IMEKO.V9I5.1005[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]