Enter your keyword

2-s2.0-85085857540

[vc_empty_space][vc_empty_space]

Advancement on Automatic Blood Pressure Measurement Using Auscultatory Method: A Literature Review

Naufal D.a, Rajab T.L.E.a, Setiawan A.W.a

a Biomedical Engineering Research Group, Institut Teknologi Bandung, Bandung, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2019 IEEE.Auscultatory method as a gold standard in determining blood pressure is subjective due to its dependency on hearing ability of each person. This subjectivity could be eliminated by establishing an instrument that is able to determine blood pressure level automatically. One of the ideas that could be proposed for developing an automatic blood pressure monitor is to automatize auscultatory method. This review presented recent development of automatic blood pressure monitor by recording Korotkoff sound and processing it digitally to determine blood pressure level and phases of the sounds that believed was associated with physiological condition. The reviewed studies showed that by processing Korotkoff sounds, the measurement results were accurate if compared with conventional method since their correlation coefficient is greater than 0.95 and the errors that obtained are less than 5 mmHg. The future work of this review is to design a similar instrumentation with different signal processing methods, i.e. discrete wavelet transform and peak finder algorithm.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Blood pressure monitors,Conventional methods,Correlation coefficient,Gold standards,Literature reviews,Physiological condition[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]diastolic blood pressure,Korotkoff phases,Korotkoff sounds,systolic blood pressure[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/ICEEI47359.2019.8988852[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]