[vc_empty_space][vc_empty_space]
Wearable gait measurement system based on accelerometer and pressure sensor
Parikesit E.a, Mengko T.L.R.a, Zakaria H.a
a Biomedical Engineering, School of Electrical Engineering and Informatics ITB, Indonesia
[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]This paper presents the development of wearable instrument that can be used to study the dynamics of human lower limb. Camera-based gait analysis and force plate system are expensive devices. It also requires time-consuming calibration and setup. The wearable system is much cheaper. This system uses gyroscopes and two-axis accelerometers to measure angle of patient’s leg and ground while the patient walks. Ground reaction forces during human walking are measured using flexible force sensors placed beneath insoles of the shoes. Communication between the wearable system and computer monitor can be performed using the wireless data communication. © 2011 IEEE.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Flexible force,Force plate,Gait measurements,Ground reaction forces,Human lower limbs,Human walking,Resistive sensor,System use,Two-axis accelerometer,Wearable systems,Wireless data communication[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Accelerometer,Force Resistive Sensor,Gait analysis,Gyroscope,Wearable System[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/ICICI-BME.2011.6108634[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]