Enter your keyword

2-s2.0-84949923117

[vc_empty_space][vc_empty_space]

Characteristics and suppression of secondary arc on 500 kV transmission lines for single pole reclosure purposes

Marojahan B.N.K.a, Hariyanto N.a, Nurdin M.a

a School of Electrical Engineering and Informatics, Insitut Teknologi Bandung, Bandung, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2014 IEEE.Single phase to ground faults are the most frequent problem in the extra high voltage overhead lines, and are temporary in most cases. This type of fault can be quickly eliminated using a single pole reclosure, but secondary arc phenomenon often makes the reclosure fail to work. This study aimed to obtain the characteristics of the secondary arc on the 500 kV transmission lines as well as obtain a solution to minimize the amplitude of secondary arc on both transposed and untransposed lines, so that the reclosure can work properly and the system maintains its stability. The effect of high speed grounding speed and neutral reactor attachment at neutral of shunt reactors on minimizing secondary arc and a possibility to activate shunt reactor only during dead time are analyzed in this study.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]500 kV transmission lines,Extra high voltage,High speed grounding switches,neutral reactor,reclosure,Secondary arc,Shunt reactors,Single phase to ground faults[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]high speed grounding switch,neutral reactor,reclosure,secondary arc[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/EECCIS.2014.7003710[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]