Sumatra-Java HVDC transmission system modelling and system impact analysis
Faizal R.a,b, Nurdin M.b, Hariyanto N.b, Pack S.c, Plesch J.c
a Sumatra Transmission and Load Dispatch Center, PLN Indonesia, Pekanbaru, Indonesia
b School of Electrical Engineering and Informatics, Institut Teknologi Bandung, Bandung, Indonesia
c Institute of High Voltage and System Management, Graz University of Technology, Austria
[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2015 IEEE.Indonesia is an archipelago country consisting of five major islands and scattered of approximately 17,000 smaller islands. It is also the fourth most populous country in the world and has relatively high energy demand, especially for electricity. The Java-Bali system is the largest electricity system and the highest electricity demand in Indonesia but with a scarce energy resource. Meanwhile, the Sumatra system has a lower electricity demand but an abundant of available energy resources. Thus, in order to increase the national electrification ratio and the power supply in Java-Bali system, a ± 500 kV high voltage direct current (HVDC) system will be operated in 2018 to transfer 3000 MW from Sumatra island to Java Island through 504 km dc transmission line (including 40 km sea-cable) by a conventional type, i.e. Line Commutated Converter (LCC). This 3000 MW is produced from 6×600 MW coal power plant located in South Sumatra. The rest of this power will be transmitted to the Sumatra System.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Defense Scheme,DIgSILENT,HVDC link,Java-Bali System,Line commutated converter (LCC),Sumatra[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Defense Scheme,DIgSILENT,HVDC link,Java-Bali System,Line Commutated Converter (LCC),Sumatra System[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/PTC.2015.7232498[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]