Enter your keyword

2-s2.0-85042785396

[vc_empty_space][vc_empty_space]

Renewable energy penetration in belitung power system

Wendha B.a, Rahmani R.a, Nurdin M.a, Hariyanto N.a

a School of Electrical Engineering and Informatics, Institut Teknologi Bandung, Bandung, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2017 IEEE.Belitung island will be developed as one of tourism economic zone. Regarding to this situation, the electricity will increase the capability of supply by using non fossil fuel power generation. Integration of intermittent renewable energy such as photovoltaic farm become a main concern in this development. This paper deal with a mechanism to calculate a maximum penetration of PV farm in the Belitung system without deterioration of existing defense scheme in the system. The calculation includes the transient effect the cloud movement toward photovoltaic farm. Beside the calculation of PV power plant, there is also the simulation of biogas penetration in Belitung Power System. Biogas power plant capacity that available in Belitung is 9.5 MW. The mitigation to make the frequency deviation smoother is also described.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Biogas power plant,Frequency deviation,Generation cost,Load flow analysis,Photovoltaic,Renewable energies,Renewable energy penetrations,Transient effect[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Biogas power plant,Generation cost analysis,Load flow analysis,Photovoltaic farm,Transients analysis[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/ICHVEPS.2017.8225933[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]