Enter your keyword

2-s2.0-85042500093

[vc_empty_space][vc_empty_space]

Ozone production based on photovoltaic source

Waluyoa, Nurendi D.M.a, Syahriala, Hariyanto N.a

a Department of Electrical Engineering, National Institute of Technology (ITENAS), Bandung, 40124, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© Medwell Journals, 2018.Ozone has been studied for various applications. Nevertheless, it is still rare that involves photovoltaic source. The research was to make designing, implementing, wave form measuring and testing the ozone generation based on solar power generation with dc-dc converter. The corona discharge current waveforms were investigated due to dc voltages. The relations among the oxygen flows, voltage levels and oxygen debits to the ozone product were also investigated. Both voltage and discharge current waveforms were measured by using a storage oscilloscope and transferred to a computer. The discharge currents were occurred in around every 72.6 μsec intermittently. It was flowed 3 and 5 L/min of oxygen. It was yielded the greatest produced ozone in the third stage of voltage, 7.047 V, 5 L/min of oxygen debit and at minute of 50 that was 0.0323 mgO3/L.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Corona,Dc-dc power conversion,Generation,Oxygen,Ozone,Solar power generation[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.3923/jeasci.2018.105.118[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]