Enter your keyword

2-s2.0-85042803141

[vc_empty_space][vc_empty_space]

Electric field analysis of 150 kV compact transmission line

Khayam U.a, Prasetyo R.a, Hidayat S.a

a School of Electrical Engineering and Informatics, Institut Teknologi Bandung, Bandung, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2017 IEEE.This paper deals with the electric field analysis of 150 kV compact transmission line. The 150 kV compact transmission line is constructed by reusing existing right of way, occupied by existing distribution lines. The 150 kV compact transmission line is designed by mutual utilization of the 150 kV transmission line with 20 kV distribution line. The electric field of the transmission line was calculated by using the method of image charges and by using the software based on Finite Element Method. The highest electric field around the 150 kV compact transmission line is 596 V/m. Therefore, the electric field due to the presence of 150 kV compact transmission line fulfills WHO standard. It appears from the calculation and simulation results that the presence of 20 kV distribution line on 150 kV compact transmission line reduces the electric field along the right of way of the transmission line.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]150 kv transmissions,Compact transmission lines,Distribution lines,Electric field analysis,K-V distribution,Method of images,Right of way[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Compact transmission line,Electric field,Right of Way,Standard[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/ICHVEPS.2017.8225883[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]