Enter your keyword

2-s2.0-77950121572

[vc_empty_space][vc_empty_space]

Development of fluxgate magnetometer using double cores probe

Djamal M.a, Setiadi R.N.a

a Research Group of Theoretical High Energy Physics and Instrumentation, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]The paper explains design and development of fluxgate magnetometer, which is based on second harmonic Fourier component. The magnetometer has double cores probe of highly saturable material and two coils, a premagnetization coil and a pick-up coil. They are used to measure an external magnetic DC or low-frequency AC field, Bext• The probe is driven periodically into saturation by a triangular current that flows through the premagnetization coil. It can be shown that the amplitude of the second harmonic frequency component will be measured by external magnetic field. The developed magnetometer can measure magnetic field with sensitivity 301.6 mV/μT and relative error < 0.017%. ©2009 IEEE.[/vc_column_text][vc_empty_space][vc_separator css=".vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}"][vc_empty_space][megatron_heading title="Author keywords" size="size-sm" text_align="text-left"][vc_column_text]AC field,Design and Development,Double core,External magnetic field,Fluxgate magnetometer,Fourier components,Low frequency,Pick-up coils,Premagnetization,Relative errors,Second harmonics,Triangular current[/vc_column_text][vc_empty_space][vc_separator css=".vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}"][vc_empty_space][megatron_heading title="Indexed keywords" size="size-sm" text_align="text-left"][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=".vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}"][vc_empty_space][megatron_heading title="Funding details" size="size-sm" text_align="text-left"][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=".vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}"][vc_empty_space][megatron_heading title="DOI" size="size-sm" text_align="text-left"][vc_column_text]https://doi.org/10.1109/ISIE.2009.5222603[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]