[vc_empty_space][vc_empty_space]
Observation on improved 20 kV’s overhead distribution lines against lightning
Zoro R.a, Mefiardhi R.a, Aritonang R.R.b, Suhana H.b
a Power Engineering Research Group, School of Electrical Engineering and Informatics, Institute of Technology Bandung, Indonesia
b PT PLN (Persero) Distribusi Jawa Barat Dan Banten, Kantor Distribusi Jawa Barat Dan Banten, Indonesia
[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]Very high power outage on distribution lines was experienced at south Jakarta, Indonesia. The annual lightning flash density in the area recorded very high, exceeding more than 15 flashes per km2. A study was carried out in this region and using lightning data from lightning detection network. Improvement of lightning protection was carried out by installing the earth wires, upgrading the insulator, improvement of grounding system and installing line arrester as well as the improvement of the installation of the arresters. Significant improvement of lightning performance was recorded after installation of lightning protection system that has been recommended by this study. Power outages associated with lightning strikes were reduced for more than 50% within 4-month observation. © 2006 IEEE.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Distribution lines,Grounding systems,Lightning performance,Line arresters[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Distribution lines,Flashover,Improvement of lightning performance,Outage[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/ICPADM.2006.284342[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]