Enter your keyword

2-s2.0-85085866455

[vc_empty_space][vc_empty_space]

Line Lightning Protection Device Analysis for 70 kV High Voltage Overhead Line in Malang

Cahya V.F.a, Zoro R.a

a School of Electrical Engineering and Informatics, Bandung Institute of Techonology, Bandung, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2019 IEEE.High voltage overhead line 70 kV was eliminated one by one because of the high amount of fault. 44% of 70 kV HV overhead line in Malang’s fault are caused by lightning. From the total fault caused by lightning, 45% had an impact on electricity outages. Hazards that appear in overhead line transmission include Back Flash Over, Shielding Failure, step voltage, and touch voltage. Analysis and evaluation is needed to provide protection device solution for HVOL 70 kV in the tropical area Indonesia, especially Malang. So that 70 kV HVOL will not be eliminated in Indonesia.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Analysis and evaluation,High voltage overhead lines,Lightning protection devices,Line transmissions,Protection device,Shielding failure,Step voltages,Touch voltage[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]70 kV HVOL,lightning,LLPD,Transmission,tropical[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/ICEEI47359.2019.8988848[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]