Enter your keyword

2-s2.0-84946685602

[vc_empty_space][vc_empty_space]

Lightning over voltage evaluation on DC 1.5 kV Overhead Contact System (OCS) for electrified railway in Indonesia

Puriza M.Y.a, Zoro R.a

a Lightning Research Center, Bandung Institute of Technology, Bandung, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2014 IEEE.Direct strike, lightning induced voltage and currents are the main cause of Overhead Contact System (OCS) major Problems also called travelling wave that can harm OCS equipments. The substations of electrical railway and Overhead Contacts Systems (OCS) in JABODETABEK area has been built long time ago, but not in accordance with the concept of ligthning protection especially lightning protection in tropical area. Mismatch between the exisitng design and the concept of lightning protection made the OCS network very vulnerable to damage by direct lightning strike or indirect lightning strike.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Direct lightning strikes,Electrified railways,Induced voltages,Lightning induced voltage,Lightning over-voltage,Lightning strikes,Overhead contact system,Protection standards[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Grounding,Induced Voltage and Current,Lightning strikes,Protection Standards[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/ICPERE.2014.7067218[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]