[vc_empty_space][vc_empty_space]
Design and testing of Rogowski Coil Based PCB Double Helix for Gas Insulated Switchgear 150 KV aplication
Wibowo H.a, Nurmansah A.P.a, Hidayat S.a
a School of Electrical Engineering and Informatics, Institut Teknologi Bandung, Bandung, Indonesia
[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2016 IEEE.Rogowski Coil is a current sensor that is often applied to the medium voltage. Rogowski Coil Based PCB Double Helix is a low-power sensor designed to measure the current that can be input into the Gas Insulation Switchgear (GIS). Not only good linearity in the measurement but also wide measurement ranges are needed to measure the disturbances on the power system. Initial signal processing circuit is required which is used for processing the sensor output waveform so that its value can present the current measured. In this paper describes the process optimization and calibration of the Rogowski coil Based PCB Double Helix currents sensor. Tests carried out using Current Transformers with 1250A maximum output current, and output rogowski sensor following the standard IEC-60044-8.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Current sensors,Gas insulated switchgears,Gas insulation switchgears (GIS),Low power sensor,Medium voltage,Rogowski Coil,Signal processing circuits,Wide measurement[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Current Transformer,low Power Sensor,Middle Voltage,Rogowski Coil[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/ICPERE.2016.7904853[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]